# Personal alert safety system (PASS)
11 12 13 14

Utilization of the PASS “Loner M6” (BlackLineSafety) available in BT1 and BT2.
PASS is a device used by a person working alone in a potentially dangerous environment.
The device allows calling for rescue in case of problem.
Laurent Heirendt's avatar
Laurent Heirendt committed
15
The call can be triggered voluntarily or automatically, in the event of a fall for example.
16 17 18 19

The lone worker should pick up and register the utilization of the PASS in the logbook.
After use, they should ensure the device is correctly plugged to charge the battery.

Laurent Heirendt's avatar
Laurent Heirendt committed
20
## 1. Overview
21

Laurent Heirendt's avatar
Laurent Heirendt committed
22
1.	The phones detect if the user is:
23

Laurent Heirendt's avatar
Laurent Heirendt committed
24 25
    a.	falling
    b.	immobile for more than 5 minutes
26

Laurent Heirendt's avatar
Laurent Heirendt committed
27 28
2.	Therefore, the PASS automatically sets off a pre-alarm, which warns the user.
If this pre-alarm is not reset, the PASS calls the emergency number 5555.
29

Laurent Heirendt's avatar
Laurent Heirendt committed
30
3.	In case of emergency, the PASS can also be used to call manually 5555.
31

Laurent Heirendt's avatar
Laurent Heirendt committed
32
4.	It is recommended when:
33

Laurent Heirendt's avatar
Laurent Heirendt committed
34 35 36
    a.	working in isolated rooms,
    b.	performing dangerous activities
    c.	working alone during the evenings or weekends
37

Laurent Heirendt's avatar
Laurent Heirendt committed
38
5.	It is forbidden to perform dangerous experiments during the night and weekends (including work with Piranha solution, highly corrosive or explosive compounds).
39

Laurent Heirendt's avatar
Laurent Heirendt committed
40
## 2. Handling the device
41 42 43

### 1. Description of the System

44
<img src="img/pass_img-1.jpg">
45

Laurent Heirendt's avatar
Laurent Heirendt committed
46 47
### 2. Quick user guide

48
<img src="img/pass_img-2.jpg">
49

Laurent Heirendt's avatar
Laurent Heirendt committed
50
### 3. How to obtain the PASS
51

Laurent Heirendt's avatar
Laurent Heirendt committed
52
1.	The PASS are stored by the guard stations in both BT1 and BT2.
53 54 55

    <div align="center">

56
    <img src="img/pass_img-3.jpg" height="300">
57

58
    <img src="img/pass_img/../pass_img-4.jpg" height="300">
59

60
    <img src="img/pass_img-5.jpg" height="300">
61

Laurent Heirendt's avatar
Laurent Heirendt committed
62
    </div>
63

Laurent Heirendt's avatar
Laurent Heirendt committed
64
2.	To obtain the PASS, place your BT2 badge in front of the lock until the light is green.
65

Laurent Heirendt's avatar
Laurent Heirendt committed
66
3.	Fill in the logbook
67 68 69

### 4. Switch on

Laurent Heirendt's avatar
Laurent Heirendt committed
70
1.	Press on the power button
71 72

2.	A single alarm will sound, the alarm light array will flash, and the device will vibrate once.
Laurent Heirendt's avatar
Laurent Heirendt committed
73
The power button and SureSafe indicator light (green) will continue to flash while establishing a network connection.
74

Laurent Heirendt's avatar
Laurent Heirendt committed
75
3.	Wait for the device to establish a network connection, which can take up to one minute.
76

Laurent Heirendt's avatar
Laurent Heirendt committed
77
4.	Once connected, the SureSafe indicator light will remain continuously on
78 79 80

### 5. Fastening the emergency phone to the clothing

Laurent Heirendt's avatar
Laurent Heirendt committed
81
5.	The PASS can be fastened to the clothes using the clip located in the back of the unit
82

Laurent Heirendt's avatar
Laurent Heirendt committed
83
6.	Hold the PASS in a vertical position while fastening it
84

Laurent Heirendt's avatar
Laurent Heirendt committed
85
### 6. Switch off
86

Laurent Heirendt's avatar
Laurent Heirendt committed
87
7.	 Press and hold the power button for approximately 3 seconds (until the device stops beeping).
88

Laurent Heirendt's avatar
Laurent Heirendt committed
89
8.	The alarm will sound three long beeps while the power button is pressed the device vibrates for three long pulses.
90

Laurent Heirendt's avatar
Laurent Heirendt committed
91
The alarm, vibration motor and power button and SureSafe indicator light will turn off after the shutdown is complete.
92

Laurent Heirendt's avatar
Laurent Heirendt committed
93
### 7. Return the PASS
94

Laurent Heirendt's avatar
Laurent Heirendt committed
95
9.	When you are done with the PASS, place it back on the charger, a red light will flash to indicate that the battery is charging.
96

Laurent Heirendt's avatar
Laurent Heirendt committed
97
10.	Fill the logbook and close the box by placing your BT2 badge in front of the lock.
98

Laurent Heirendt's avatar
Laurent Heirendt committed
99
## 3. Types of alerts
100

Laurent Heirendt's avatar
Laurent Heirendt committed
101
### 1. Emergency alert
102

Laurent Heirendt's avatar
Laurent Heirendt committed
103
1.	Pull the emergency latch. The device will instantly send an emergency message to the 5555.
104

Laurent Heirendt's avatar
Laurent Heirendt committed
105
2.	The device will trigger the “high alarm” pattern to notify others nearby of the event.
106

Laurent Heirendt's avatar
Laurent Heirendt committed
107
3.	To silence the alert, return the emergency latch to the closed position.
108 109

4.	Press and hold the acknowledge button until the alarm pattern is silenced (approximately 3 seconds).
Laurent Heirendt's avatar
Laurent Heirendt committed
110
The device will return to regular operation.
111

112
5. <img src="img/pass_img-6.jpg"> silencing the alert will not cancel it: the 5555 will still intervene.
113

Laurent Heirendt's avatar
Laurent Heirendt committed
114
### 2. Fall impact detected alert
115

Laurent Heirendt's avatar
Laurent Heirendt committed
116
The device is constantly monitoring your motion or falls. If the device detects a fall impact, it will trigger the “pending alarm” mode.
117

Laurent Heirendt's avatar
Laurent Heirendt committed
118
If you do not require assistance, you have 30 seconds to cancel the alert by pressing on the acknowledge button.
119

Laurent Heirendt's avatar
Laurent Heirendt committed
120
1.	Cancelling a pending fall detected alert
121

Laurent Heirendt's avatar
Laurent Heirendt committed
122
    a.	The device will start a pending alarm
123 124

    b.	Press the acknowledge button until the alarm pattern is silenced   (approximately 1 second).
Laurent Heirendt's avatar
Laurent Heirendt committed
125
    The device will return to regular operation
126

Laurent Heirendt's avatar
Laurent Heirendt committed
127
2.	Silencing a fall detected alert
128

Laurent Heirendt's avatar
Laurent Heirendt committed
129
    a. If you have not cancelled the alert within 30 seconds, the fall detected alert is communicated to the 5555
130

Laurent Heirendt's avatar
Laurent Heirendt committed
131
    b.	The device will go to “high alarm”
132 133

    c.	Press and hold the acknowledgement button until the alarm pattern is silenced (approximately 3 seconds).
Laurent Heirendt's avatar
Laurent Heirendt committed
134
    The device will return to regular operation
135

136
    d. <img src="img/pass_img-6.jpg"> Silencing an alarm will not cancel the call, 5555 will still intervene.
137

Laurent Heirendt's avatar
Laurent Heirendt committed
138
### 3. No-motion alert
139 140 141 142 143

The device is constantly monitoring your motion to detect a possible person down incident.
If the device has not detected motion within 5 minutes, it will prompt you to acknowledge your safety, entering the alarm mode and triggering the low alarm pattern.
If you do not require assistance, you have 30 seconds to cancel the alert by pressing on the acknowledgement button.

Laurent Heirendt's avatar
Laurent Heirendt committed
144
1.	Cancelling a pending no-motion alert
145

Laurent Heirendt's avatar
Laurent Heirendt committed
146
    a.	The device will start a “pending alarm”
147

Laurent Heirendt's avatar
Laurent Heirendt committed
148 149
    b.	Press the acknowledge button until the alarm pattern is silenced (approximately 1 second).
    The device will return to regular operation.
150

Laurent Heirendt's avatar
Laurent Heirendt committed
151
2.	Silencing a no-motion alert
152

Laurent Heirendt's avatar
Laurent Heirendt committed
153
    a.	If you have not cancelled the alert within 30 seconds, the no-motion alert is communicated to 5555.
154

Laurent Heirendt's avatar
Laurent Heirendt committed
155
    b.	The device will trigger the “high alarm” pattern and will continue until the alert is cancelled or the battery runs out.
156 157

    c.	Press and hold the acknowledge button until the alarm pattern is silenced (approximately 3 seconds).
Laurent Heirendt's avatar
Laurent Heirendt committed
158
    The device will return to regular operation.
159

160
    d. <img src="img/pass_img-6.jpg"> Silencing an alarm will not cancel the call, 5555 will still intervene.
161

Laurent Heirendt's avatar
Laurent Heirendt committed
162
### 4. Voice call alert
163

Laurent Heirendt's avatar
Laurent Heirendt committed
164
1.	When a phone call has been initiated by 5555, the device will trigger the “high alarm” pattern accompanied by a blue flashing of the LiveResponse light.
165

Laurent Heirendt's avatar
Laurent Heirendt committed
166
2.	To silence the alarm, press and hold the acknowledge button until the alarm is silenced (approximately 3 seconds).
167

Laurent Heirendt's avatar
Laurent Heirendt committed
168
3.	The LiveResponse confirmation light will continue to flash, signifying that an incoming call has been initiated.
169

Laurent Heirendt's avatar
Laurent Heirendt committed
170
4.	Once the call has been connected, the device will generate a long beep signifying the beginning of the two-way  voice calling.
171

Laurent Heirendt's avatar
Laurent Heirendt committed
172
5.	In a noisy environment, it may be necessary to remove and hold the device near your face, as you would do with a two-way radio.
173 174

6.	Once the call is complete, the caller will end the call.
Laurent Heirendt's avatar
Laurent Heirendt committed
175
The device will trigger a long beep signifying the end of the call.
176

Laurent Heirendt's avatar
Laurent Heirendt committed
177
7.	The device user cannot end the call.
178

Laurent Heirendt's avatar
Laurent Heirendt committed
179
8.	The LiveResponse confirmation light on the device will go off once the call has ended.
180

Laurent Heirendt's avatar
Laurent Heirendt committed
181
9.	NOTE: during the call, the volume of the speaker can be switched to speaker and back to lower volume by pressing the acknowledge button once.
182

Laurent Heirendt's avatar
Laurent Heirendt committed
183
### 5. Low battery notification
184 185 186 187 188

1.	If the battery level on the device drops below 20% capacity, the device will flash the charging light and beep once every 5 minutes.
Once the device battery is depleted, it will automatically shut down.

2.	This is considered an unsafe log off.
Laurent Heirendt's avatar
Laurent Heirendt committed
189
If the device is configured to require a periodic check-in, a low battery shutdown will not stop the timer and a missed check-in alter will be generated.
190 191 192

## 4. Types of alarms

Laurent Heirendt's avatar
Laurent Heirendt committed
193 194 195 196
|Type|Beeper|Vibration|Visual indicator|
|----|------|---------|----------------|
|**Pending alarm**|Slow alarm pattern|Single repeating vibration|Alarm light array slow flash (red)|
|**High alarm**| Fast alarm pattern| Double repeating vibration|Alarm light array fast flash (red)|
Jacek Lebioda's avatar
Jacek Lebioda committed
197
|**Low battery**|Single beep once every 5 minutes|No vibration|Charge light, single flash once every 5 minutes|